What to look for in a Manassas HVAC company?
61A Quality Manassas HVAC Company?
HVAC systems are specific to the areas where they are to be installed. Secondly, HVAC systems gradually become less efficient and proper functioning of the HVAC system is essential if you are worried about high energy costs. A quality Manassas HVAC company can help in providing you the information you need about the type of HVAC system you require and how to save on energy costs.
The story does not end with installing a good HVAC system. The term stands for heating, ventilation and air conditioning. It is basically climate control that you are looking at and for that all three issues need to be addressed. That would mean that HVAC systems should have appropriate thermostat settings and home insulation after due consideration to local climate conditions.
A quality Manassas HVAC company considers all these aspects of thermal and climate control to provide satisfactory indoor comfort no matter whether it is the winter chill or hot summers that is bothering you.
Depending upon which part of the country you live in, HVAC systems have two contrary issues to address. During hot weather there is a need for cool air while in winters the indoor temperatures have to be increased for indoor comfort. For that, you need a local HVAC contractor who is familiar with local climate conditions. A quality Manassas HVAC company provides services for regular inspections, scheduled servicing and ensuring that your HVAC system consumes only the minimum required energy.
A quality Manassas HVAC company is committed to provide maximum comfort and minimal cost.
Advancement in technology has made it possible to customize HVAC systems according to local needs. Modern HVAC systems consume less energy and built according to need. There may be a case where air conditioning is not required and a forced air system may serve your needs better. Also, the local climate determines whether you need water, geothermal or zoned heating.
Energy consumption depends largely upon the electric heat pump that is installed in the HVAC system provided that you use electricity. There is a wide variety of heat pumps available but an appropriate heating system can amount to as much as 33% saving in energy costs.
Bigger air conditioners are not always the best. The fact is that inappropriate sizes are waste of money and also wasteful use of electricity. The size of the air conditioner depends solely on the size of the room and whether the room is on ground or top floor.
If it is a gas or oil furnace then your fuel costs depend upon the percentage of fuel reaching the ducts as heat. A quality Manassas HVAC company can help you in choosing HVAC systems that ensure 90% fuel efficiency.
This is but a part of the benefits that you can expect when you consult with a quality Manassas HVAC company. For fuel efficient HVAC systems in Manassas, Virginia or Northern Virginia you can depend upon this reputable company. Turner Service Co is an authorized dealer for fuel efficient HVAC systems and also provides annual service contracts to keep your HVAC system working at optimal fuel efficiency for better indoor comfort.
Manassas HVAC Company Photos
CommentsLoading...
COVER LETTER
My name is Johnson-Kwame Amuzuvi, I am a highly motivated HVAC Mechanic and am always ready for a challenge.
I have extensive experience in Repairing, Servicing, installation, System maintenance and General electrical works and I am actively seeking a position that fits my skills and experiences.
I am a hard-working person, team-player and I am able to work anywhere anytime in any conditions/climate. I take too much concentration when I am at work and I like to get information from my elder/fellows for sharing knowledge together as one and I make ready to learn from any one at work place, I also like Problem solving, Decision making, Critical thinking, Job task planning, creativity and organizing, Finding information and Continuous learning.
Please review my resume to see further details of my work experience.
RESUME LETTER
Johnson-Kwame Amuzuvi
Box: 13Atiavi-Abor, Volta R-Ghana. (233) 277076104 / 242953858 amuzuvijohnson@yahoo.com
Completed (ASHRAE-learning), in A/C System Design Manual with 24.5PDHs,
Also having Energy Saving for Small Office Building with 7.5 and
Also have study Note from (fgas-support@globalskm.com, www.cityandguilds.com/uk-home.html).
Fundamental of Electricity with 1.75-PDHs and Fundamental of Electricity possessing HVAC Mechanic
SUMMARY OF QUALIFICATIONS
•?Pass all requirements for A/C System Design Manual examination, gaining certificate as Professional Development Hours (PDHs)
•?Successful completed Accra Technical Training School for four years as Refrigeration and Air-conditioning Mechanic, holding position for five years now.
Led ten-member senior mechanic team, including installation, servicing, repairs, maintenance and general electrical maintenance
EDUCATION AND TRAINING
Professional Develop Hours, A/C System Design Manual
ASHRAE-elearning.org 2008-2010
A/C System Design Manual-24.5PDHs
Energy Saving for Small Office Building-7.5PDHs
Fundamental of Electricity-1.75PDHs
Diploma in Refrigeration and Air-Conditioning-(B, C) 2004-2008
COURSES TAKEN INCLUDE:
•?HVAC&R Controls
•?Special HVAC Systems
•?All-Water Systems
•?Air-and-Water Systems
•?Air-Conditioning Systems Components - Heat Transfer Equipment
•?Air-Conditioning Systems Components - Pumps, Valves, Piping, and Duct-work
•?Simple Rooftop All-Air Systems
•?Dual-Duct and Multi zone All-Air Systems
•?Air-Conditioning Systems Components - Source Equipment
•?The Design Process
•?HVAC System Selection Issues
•?Load Calculations
•?Design Strategies and Recommendation Building enveloped
•?Lighting
•?HVAC Equipment and Systems Service Water Heating
•?Direct current electrical systems Bonus Savings
•?Alternative current electrical systems
SENIOR HVAC MECHANIC TEAM
Installation, servicing, repairs, maintenance and general electrical maintenance team, co-captain 2004-2010 Part of team of ten senior building an amphibious
WORK EXPERIENCE
(HVAC&R) Heating Ventilation Air-conditioning and Refrigeration 2005-2010
2: Johnson-Kwame Amuzuvi
Box: 13Atiavi-Abor, Volta R-Ghana. (233) 277076104 / 242953858 amuzuvijohnson@yahoo.com
OBJECTIVE: HVAC Mechanic career in servicing, installation, maintenance and system repairs.
SUMMARY:
1 Certified as HVAC Mechanic-in-training
2 Completed Four years Tech Training School
3 Completed Senior High School
EDUCATION:
Professional Development Hours in A/C System Design Manual -IP (Cumulative of 24.5PDHs on a scale of 30)
Professional Development Hours in Energy saving or Small Office Building-IP (Cumulative of 7.5PDHs on a scale of 10)
Professional Development Hours in Fundamental of Electricity-(Cumulative of 7.5PDHs on a scale of 10)
Diploma in Refrigeration and Air-Conditioning-(Cumulative of B, C on a scale of
Experience
HVAC Mechanic, April 2005, 18 up to date
CERTIFICATION:
•Pass for A/C System Design Manual-IP (24.5out of 30PDHs)
•Pass for Energy Saving of Small Office Building-IP (7.5 out of 10PDHs)
•Pass for Fundamental of Electricity-IP (1.75 out of 2PDHs)
•?Pass for Refrigeration and Air-conditioning-(B, C out of AA)
ACTIVITY
Installation, servicing, repairs, maintenance and general electrical maintenance
1-Installation, A/C Installation - In the first box, you will find the interior unit of the Air-conditioner system together with a remote-control and water drainage pipe.
You need to remove the wall-bracket to position on the wall and after install the wall bracket
Carefully make the place where the hole will drill
Measure the dimension of the pipe package and mark the wall support, measure the center of the pipe to the bottom of the system, use that measurement to mark on the wall again.
Now take a drilling machine to drill a hole carefully at angle of 35, before the unit will fix, you need to tape the drainage pipe together of refrigerant pipes with electrical cable for easier to pass through the hole.
In the second box, you will find the system/Outdoor unit together with connecting pipes, finishing cover, a rolling thermal tape……
Before fixing the system, you need measure the length of the system seat between the first and the second, and mark the wall where the system stand/wall bracket will fix. Before fixing the system stand/wall bracket, if the wall is solid, use mental wall plug supply and if the wall is hollow-blocks, use chemical sealed wall plug.
After install the system, you now needs to connect the connecting pipes together with indoor unit and outdoor unit by tighten them with care. Use Allan-key to open the valves for gas to flow through the pipes and after that, use soap water to check leakage, then use the take to take all the pipe and finally connect wires to correct positions, e.g. blue to blue, please measure the voltage before you can plug the system for testing.
NOTE: Never installed the system at direct sunlight, wine path, water area and make sure water drainage pipe slope down-ward.
Some times during the installation you need to add pipe like 6 to 12feets or more than, if that need to happen, you need short the capillary by some percentage that can feet the system and sometimes you need to add gas, adding more refrigerant which sometimes will result, the compressor will over-heat, more current/amps will be drawing during operation.
In case if the system is using Thermostatic expansion, you need to adjust it and if it is Automatic expansion valve, that one can work by itself or u need to change it ...........ect.
2-Air-conditioning servicing, A/C Servicing indoor unit –before dismantling, you need to pump-down refrigerant not to escape or not loose. First dismantling and cleaning a wall Mounted Air Conditioner Unit, The Mounting bracket and piping after removing the air con and close the pipes so that no moisture, water or any things not allow to enter the pipes.
The air con after disconnected from cooling pipes and dismounted from the wall unit
The electronic assembles and the blower fan motor needs to remove from the main unit, this is to prevent water not to enter the fan-motor or splash on the electronic board, that will cause damage to them.
Part of the air deflector, full of mold.
Air deflector unit, moldy growth adhering to surface,
The cooling coil disconnected.
The back plastic housing of the air-con, Moldy and dirty
Prepare to clean the cover with chemical solution
Chemical solution sprayed on the cooling coil.
Drying out the clean parts
The cleaned cooling coil drying out, Reassembled and reconnected air-con
And regular filter cleaning.
3-Maintenance, SAFETY FIRST
Before working on your air conditioner, please be a ware of the following rules.
•Have moving parts that can be cut, pinch, entangle or hurt you.
•?Are electrically powered and used high level of current to function, and electricity can burn, shock or kill you
•?Contained a capacitor that hold an electrical charged which can hunt you.
•Contain a pressure refrigerant lines, if broken it will cause injury or frostbite from rap








Joe 24 months ago
Thanks for the great information.